28 – 480 HEIDENHAIN Service Manual iTNC 530 HSCI
Adapter for connecting the TT touch probe to a PLB 62xx up to variant 02:
This adapter makes the Start and Ready signals available on the correct pins of X113.
Pin layout of adapter with ID 667 674-01:
(15-pin D-sub, triple-row)
X344:
24 V power supply
for motor holding
brakes
X394:
Motor holding
brakes
X201 to X205:
Position encoder
See “X201 to X206: Position encoder 1 Vpp” on page 28 – 470.
X500, X502:
HSCI interfaces
See “X500, X502: HSCI interfaces” on page 28 – 472.
Female Assignment of X113
(TT) up to variant 02
Adapter
ID 667 674-01
TT adapter cable
ID 633 616-xx
1 Trigger signal Trigger signal
2 Trigger signal
a
Trigger signal
a
3 TS ready Do not assign
4 Battery warning
Battery warning
5 + 5 V-NC (+/- 5%) + 5 V-NC (+/- 5%)
6 Start Do not assign
7 0 V-NC TT start
80V-NC 0V-NC
90V-NC 0V-NC
10 + 24 V-NC + 24 V-NC
11 TT ready TT ready
12 Do not assign Do not assign
13 Do not assign Do not assign
14 Do not assign Do not assign
15 Do not assign Do not assign
Connecting terminals Assignment
1+24V PLC
2 0 V PLC
Connecting terminals Assignment
1 Holding brake 1 (X81)
2 0 V PLC
3 Holding brake 2 (X82)
4 0 V PLC
5 Holding brake 3 (X83)
6 0 V PLC
7 Holding brake 4 (X84)
8 0 V PLC