28 – 512 HEIDENHAIN Service Manual iTNC 530 HSCI
Adapter
TTL (HEIDENHAIN)/
1 Vpp
Pin layout of D-sub connector (female) and D-sub connector (male):
Adapters for encoder signals ID
TTL (HEIDENHAIN layout)/1 V
PP
317 505-01
TTL (SIEMENS layout)/1 V
PP
317 505-02
11 µA
PP
to MC 6xxx 317 505-05
11 µA
PP
/1 V
PP
313 119-01
Note
Please note:
The adapters adjust only the levels, not the signal shape.
The contamination signal of the square-wave encoder cannot be evaluated.
A square-wave signal can be subdivided no more than 4-fold.
If encoders with TTL signals are connected to a CC 61xx via an adapter (ID 317505-xx), then
the phase position of the reference pulse is not correct. In order to deactivate monitoring, set
bit 9 of MP2220.
D-sub connector
(female), 15-pin
Assignment D-sub connection
(male), 15-pin
Assignment
1+5 V (U
P
) 1 +5 V (U
P
)
2 0 V (U
N
)2 0 V (U
N
)
3A+3U
a1
4A4–U
a1
5 Not assigned 5 Not assigned
6B+6U
a2
7B7–U
a2
8 Not assigned 8 Not assigned
9 +5 V 9 +5 V
10 R+ 10 U
a0
11 0 V 11 0 V
12 R– 12 –U
a0
13 Not assigned 13 Not assigned
14 Do not assign
a
a. The control assigns the EnDat clock to pin 14. Therefore, you must not assign any signals
to this pin when using the TTL adapter connector.
14 Do not assign
a
15 Not assigned 15 Not assigned