31 – 592 HEIDENHAIN Service Manual iTNC 530 HSCI
31.4.4 Operation with following error
MP Function and input Software
version and
behavior
MP1710.x Position monitoring for operation with following error (erasable)
Input: 0.0000 to 300.0000 [mm]
Recommended: 1.2 following error
PLC
RUN
MP1720.x Position monitoring for operation with following error (emergency stop)
Input: 0.0000 to 300.0000 [mm]
Recommended: 1.4 following error
PLC
RUN
MP1810.x k
V
factor for control with following error
Input: 0.100 to 20.000 [(m/min)/mm]
PLC
RUN
MP1815.x k
V
factor for control with following error effective after M105
Input: 0.100 to 20.000 [(m/min)/mm]
PLC
RUN
MP1820.x Multiplier for the k
v
factor
Input: 0.001 to 1.00000
PLC
RUN
MP1830.x Characteristic curve kink point
Input: 0.000 to 100.000 [%]
PLC
RUN