July 2010 10 – 101
8 Use the cursor to select a value and confirm it with the ENT key.
Mode of operation 8 Select the desired setting or choose the circular interpolation test.
YT: Chronological depiction of the channels (function of the time)
XY: X/Y graph of two channels
CIRC: Circular form test
Sample time
8 Set the time interval for recording the signals.
Enter, e.g., 0.6 ms, 1.8 ms and 3.6 ms (depending on the set cycle times).
4096 grid points are saved. The time interval determines the duration of recording.
Example:
0.6 ms x 4096 = 2.4576 s
1.8 ms x 4096 = 7.3728 s
3.6 ms x 4096 = 14.7456 s