July 2010 13 – 183
Configuration of
the serial interface
on the iTNC
8 Call --> See “Interface configuration and assignment of mode” on page 13 – 206
8 Select the baud rate for the LSV/2 protocol.
You can select the highest possible baud rate. If there are transmission problems, you can
back on lower baud rates.
TNCremoNT
8 Start the HEIDENHAIN data transfer program TNCremoNT.
8 Click this icon to open the configuration windows.
(Can also be called via Extras / Configuration ... .)
8 Click now on Connection and select the LSV-2 (serial connection).
8 Then click on Settings and select the serial interface (e.g. COM1).
8 Activate automatic detection of the data transfer rate on connection setup. --> The baud rate
you have set on iTNC 530 is activated.
Note
The iTNC 530 recognizes automatically when the LSV-2 protocol is used
(e.g., data transfer with TNCremoNT).
A setting in the line Operating mode is not necessary!
Note
If you use a USB/RS -232-C adapter, automatic detection of the baud rate should not be
active. In this event set the transfer rate at the control and at the laptop to the same value.