13 – 190 HEIDENHAIN Service Manual iTNC 530
Reading out data
using TNCremoNT
In the upper half of the screen (laptop/PC contents), select the target drive and the target
directory:
8 Click the bar with the drive information. --> Its color changes from gray to blue, and two
buttons appear at the right side in the bar.
8 Click the Change folder/drive... button. --> A new window opens.
8 Now, select the drive and the folder. --> The path is displayed in the blue bar.
In the lower screen half (iTNC 530 contents), select the source drive and the source directory:
8 Click the bar with the drive information. --> Its color changes from gray to blue, and two
buttons appear at the right side in the bar.
8 Click the Change folder/drive... button. --> A new window opens.
8 Now, select the drive and the folder. --> The path is displayed in the blue bar.
Figure: Changing to the PLC partition
Transfer the data:
8 Using the mouse, click the directory you wish to read out.
8 Press and hold the left mouse button and pull the directory or the file into the upper window.
8 Release the mouse button. --> The file is being transferred.
For the data zu be read out, you can create a folder on your laptop with TNCremoNT. For this
purpose, click the icon Create folder or select File / Create folder ... from the menu.
For changing to the PLC: und SYS: control partitions, the respective code numbers are
interrogated.