15 – 226 HEIDENHAIN Service Manual iTNC 530
15.5 Execution as of NC Software 34049x-02 (Dual-Processor Version)
Unzipping the
ZIP File
The provided ZIP file (e.g., 34049204sp6.zip) has still to be unzipped on a data medium
(PC/laptop/USB stick)!
A folder with the number of the NC software (e.g., 34049204) is created.
This folder contains a subdirectory (e.g., 340492_004_SP6), of the following files:
setup.exe
setup.ini (optional)
setup.zip
Access to the
service pack files
via the customer
network
If the control is connected to the company network and the service pack files were filed on a
released folder of the network, you have access to these data. --> If necessary, ask the system
administrator.
You may also use a USB stick as data medium.
Loading the
service pack
8 Connect the USB stick to X141 or X142 (USB interfaces of the iTNC 530).
8 Press the Windows key to display the taskbar.
8 With the Windows explorer, e.g., open the folder on the USB stick, that contains the service
pack.
Caution
With the dual-processor version of the iTNC 530 as of NC software 34049x-02, service
packs are installed with Windows.
A corresponding Windows authorization is required.
If necessary, ask the machine manufacturer!
Note
When connecting, USB memory devices that use the file system VFAT or ISO 9660
(not NTFS or similar) are detected automatically.