EasyManua.ls Logo

HEIDENHAIN ITNC 530 - Page 281

HEIDENHAIN ITNC 530
696 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
July 2010 18 – 281
Flowchart
No
Yes
The defect is probably located in the position
encoder input of the control.
Shut down the control and switch off
the main switch of machine.
Switch on the main switch of machine.
Defect is located in the position
encoder or the encoder cable.
Do not confirm the Power interrupted
message but immediately call the MP list and
interchange the entry values in MP110.x
of the axes concerned
(in the example: MP 110.0: 2 and MP 110.1: 1)
If required also interchange the values in
MP 115.0 and MP 115.2 and
MP 116.0 and MP 116.2
(signal type and input frequency).
Interchange the position encoder cables on the
MC or CC 424 for the axes concerned
(in the example: connectors X1 and X2
on the MC).
Does the error
pattern move to the other axis?
(In the example:
from X to Y)
Interchanging the position encoders
Switch on the machine and traverse the axes.
Yes

Table of Contents

Other manuals for HEIDENHAIN ITNC 530

Related product manuals