July 2010 27 – 485
X149:
BF 150 flat-panel
display
D-sub connector, 44-pin
MC 42x (B/C), X149 Connecting cable ID 353 545-xx BF 150,
X2
Female
Pin layout Male Female
Male
1A7M1 11
2 A6M 2 White/Brown 2 2
3 A5M 3 White/Green 3 3
4A4M4Red/Gray44
5A3M 55
6 CLKM 6 Red/Blue 6 6
7 A2M 7 White/Orange 7 7
8 A1M 8 Red/Brown 8 8
9 A0M 9 Red/Green 9 9
10 LVDSGND 10 Red/Orange 10 10
11 HWK_GND 11 Orange/Red 11 11
12 HWK0 12 White/Blue 12 12
13 HWK1 13 Blue/White 13 13
14 HWK2 14 White/Blue 14 14
15 HWK3 15 Gray/White 15 15
16 A7P 16 16 16
17 A6P 17 Brown/White 17 17
18 A5P 18 Green/White 18 18
19 A4P 19 Gray/Red 19 19
20 A3P 20 20
21 CLKP 21 Blue/Red 21 21
22 A2P 22 Orange/White 22 22
23 A1P 23 Brown/Red 23 23
24 A0P 24 Green/Red 24 24
25 to 30 Not assigned 25 to 30 25 to 30
31 to 39 LVDSGND 31 to 39 31 to 39
40 to 44 Not assigned 40 to 44 40 to 44
Housing Housing Housing Housing
The interface complies with the requirements of EN 61800-5-1 for "protective extra-low
voltage" (PELV).
Only units that comply with the requirements of EN 61800-5-1 for "protective extra-low
voltage" (PELV) may be connected.