30 – 582 HEIDENHAIN Service Manual iTNC 530
MP116.0 Only CC 424(B): Position encoder input 1 Vpp or 11 µApp
Format: %xxxxxxxxxx
Input: Bit 0 to bit 9: Linear encoder inputs X201 to X210
Bit 10: No function
0: 1 Vpp
1: 11 µApp
RESET
340 420-08,
340 422-02,
340 480-02
MP116.1 CC 424(B) only: Reserved
Format: %xxxxxxxxxxx
Input: Enter %00000000000
MP116.2 Only CC 424(B): Input frequency of the position encoder inputs
Format: %xxxxxxxxxxx
Input: Bit 0 to bit 9: Linear encoder inputs X201 to X210
Bit 10: No function
With 1 Vpp:
0: 27 kHz
1: 400 kHz
With 11 µApp:
0: 27 kHz
1: 140 kHz
MP120.x Nominal speed command outputs of the axes
Input: 0: No servo-controlled axis
1 to 6: Analog outputs 1 to 6 at terminal X8
7 to 12: Analog outputs 7 to 12 at terminal X9
51 to 62: Digital output X51 to X62
RESET
MP121.0 Nominal speed command output of the first spindle
Input: 0: No servo-controlled axis
1 to 6: Analog outputs 1 to 6 at terminal X8
7 to 12: Analog outputs 7 to 13 at terminal X9
51 to 62: Digital output X51 to X62
RESET
MP121.1 Nominal speed command output of the second spindle
Input: 0: No servo-controlled axis
1 to 6: Analog outputs 1 to 6 at terminal X8
7 to 12: Analog outputs 7 to 13 at terminal X9
51 to 62: Digital output X51 to X62
RESET
MP130.x Y index of the machine parameters MP2xxx.y for the axes
Input: 0 to 12
PLC
RUN
MP131.x Y index of the machine parameters MP2xxx.y for the spindle(s) in operating mode 0
Input: 0 to 12
PLC
RUN
MP131.0 Index for the first spindle
MP131.1 Index for the second spindle
MP132.x Y index of the machine parameters MP2xxx.y for the spindle(s) in operating mode 1
Input: 0 to 12
PLC
RUN
MP132.0 Index for the first spindle
MP132.1 Index for the second spindle
MP210 Counting direction of position encoder output signals
Format: %xxxxxxxxxxxxxx
Input: Bits 0 to 13 represent axes 1 to 14
0: Positive
1: Negative
REF
MP331.x Distance for the number of signal periods in MP332
Input: 0.0001 to +1.797693135E+308 [mm] or [°]
PLC
RUN
REF