30 – 618 HEIDENHAIN Service Manual iTNC 530
MP7230.x Dialog language
Input: 0: English
1: German
2: Czech
3: French
4: Italian
5: Spanish
6: Portuguese
7: Swedish
8: Danish
9: Finnish
10: Dutch
11: Polish
12: Hungarian
13: Reserved
14: Russian (Cyrillic characters)
15: Chinese (simplified)
16: Chinese (traditional)
17: Slovenian (option #41)
18: Norwegian (option #41)
19: Slovak (option #41)
20: Latvian (option #41)
21: Korean (option #41)
22: Estonian (option #41)
23: Turkish (option #41)
24: Romanian (option #41)
14, 15, 16 and 17 only in connection with BF 150
PLC
RUN
CN123
340 490-04
MP7230.0 NC conversational language, soft keys for OEM cycles
MP7230.1 PLC conversational language (user parameters)
MP7230.2 PLC error messages
MP7230.3 Help files
MP7235 Time difference to Universal Time (Greenwich Mean Time)
Input: –23 to +23 [hours]
MP REMOVED as of 340 490-03
No longer
used as of
340 480-03,
340 49x-03
CN123
RESET
MP7237 Displaying and resetting the operating times PLC
RUN
MP7237.0 Display PLC operating times
Input: Bits 0 to 12 represent PLC operating times 1 to 13
0: Do not display
1: Display
MP7237.1 Reset PLC operating times with code number 857282
Input: Bits 0 to 12 represent PLC operating times 1 to 13
0: Do not reset
1: Reset
MP7237.2 Reset NC operating times with code number 857282
Input: Bit 0 – No function
Bit 1 – “Machine on” operating time
Bit 2 – “Program run” operating time
0: Do not reset
1: Reset
MP7238.0-12 Dialog messages for PLC operating times 1 to 13
Input: 0 to 4095
Dialog no. from the file (OEM.SYS)
PLC
RUN
MP Function and input SW version