July 2010 30 – 637
MP7671 Handwheel feed rate in the Handwheel operating mode with HR 410
Input: 0 to 1000 [% of MP1020]
PLC
RUN
MP7671.0 Low speed
MP7671.1 Medium speed (only HR 410)
MP7671.2 High speed (only HR 410)
MP7672 HR 410, distance per handwheel step
Input: 0.0000 to 1.0000 [mm]
340 490-03
MP7672.0 Low speed
MP7672.1 Medium speed
MP7672.2 Fast speed
MP7674.x Handwheel, axis-specific subdivision factor
Input: 1 to 10
0: No limitation
PLC
RUN
340 490-03
MP7675.x Handwheel, axis-specific maximum path
Input: 0.0001 to 1.0000 [mm]
0: No limitation
PLC
RUN
340 490-03
MP7680 Machine parameter with multiple function
Format: %xxxxxxxxxxxxxxx
Input: Bit 0 – Memory function for axis-direction keys with M4562:
0: Not saved
1: Saved if M4562 is set
Bit 1 – Returning to the contour
0: Not active
1: Active
Bit 2 – Block scan
0: Not active
1: Active
Bit 3 – Interruption of block scan for STOP or M06
0: Interruption
1: No interruption
Bit 4 – Inclusion of programmed dwell time during the block scan
0: Include the dwell time
1: Do not include the dwell time
Bit 5 – Start of calculation for block scan
0: Start from block with cursor
1: Start from beginning of program
Bit 6 – Tool length in blocks with normal vectors
0: Without R2 from tool table (south pole)
1: With R2 from tool table (center of sphere)
Bit 7 – Inserting a defined rounding arc or spline
0: Defined rounding arcs are always inserted
1: Defined rounding arcs are always inserted if the acceleration from MP1060.x or
MP1070 was exceeded.
PLC
RUN
MP Function and input SW version
and
behavior