January 2012 6.22 Diagnosis with the Online Monitor (OLM) 1187
Deleting the
following error
(Clear PeakLag)
The IPO saves the greatest following error (PeakLag) that occurred. The Clear
PeakLag function deletes this variable for all axes.
To select the Clear PeakLag function:
Press the Login Ipo (or Login SimIpo) soft key.
Press the Axes soft key.
Press the Clear PeakLag soft key.
Deleting the
reference point
(Clear RefOk)
Deleting the reference point is necessary for being able to assign a new
reference-run command. The function is effective for all axes.
To select the Clear RefOK function:
Press the Login Ipo (or Login SimIpo) soft key.
Press the Axes soft key.
Press the Clear RefOK soft key.