424 HEIDENHAIN Technical Manual MANUALplus 620
powerOffPort
101606
MP4041
(optional parameter)
Number of terminal in the PL module or on the
internal PL
System with HSCI interface:
Enter the number of the PLC output of the
module, which is to be set after shutting down.
System without HSCI interface:
Enter the number of the PLC output of the
integrated PL, which is to be set after shutting
down.
Format: Numerical value
Input: 0 to 31
Default: 0
PLC/Pgm
run is
locked
LEVEL1
1323
powerOffDelay
101607
MP4042
(optional parameter)
Delay time until the PLC output is set
Time after shutting down the control until the PLC
output from MP_powerOffPort is set.
Format: Numerical value
Input: 0 to 1000 [s]
Default: 0 [s]
PLC/Pgm
run is
locked
LEVEL1
1323
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page