452 HEIDENHAIN Technical Manual MANUALplus 620
acknowledge
104104
(optional parameter)
Symbolic name or number of the PLC marker
that is set for acknowledging the strobe
No input:
The strobe is reset with the PLC marker entered
in MP_signal.
Format: String
Input: PLC operand, max. 80 characters
RESET
LEVEL3
1577
toolNumber
104105
(optional parameter)
Symbolic name or number of the PLC word for
transmitting the tool number
No input:
The tool number cannot be read as a numerical
value.
Format: String
Input: PLC operand, max. 80 characters
RESET
LEVEL3
1577
toolIndex
104106
(optional parameter)
Symbolic name or number of the PLC word for
transmitting the tool index
No input:
The index cannot be read as a numerical value.
Input: String, max. 24 characters
RESET
LEVEL3
1578
toolMagazine
104107
(optional parameter)
Symbolic name or number of the PLC word for
transmitting the magazine number of the tool
No input:
The magazine number cannot be read as a
numerical value.
Format: String
Input: PLC operand, max. 80 characters
RESET
LEVEL3
1578
pocketNumber
104108
(optional parameter)
Symbolic name or number of the PLC word for
transmitting the pocket number of the tool
No input:
The pocket number cannot be read as a numerical
value.
Format: String
Input: PLC operand, max. 80 characters
RESET
LEVEL3
1578
unloadTool
104109
(optional parameter)
Symbolic name or number of the PLC marker
that is set during decoding if no tool is loaded
The definition of this marker is not necessary, if
the T0 and T1 strobes are otherwise
distinguished.
Format: String
Input: PLC operand, max. 80 characters
RESET
LEVEL3
597 110-03
1578
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page