456 HEIDENHAIN Technical Manual MANUALplus 620
CfgPlcStrobeAlias
Conversion to M functions;
Reproduction of control-dependent functions through the output of M functions to the PLC program.
[Key names of the converted functions (alias strobes)]
e.g. GFUNCTION, TCHPROBE etc.
type
104201
Type of alias strobe
Format: Selection menu
Input:
FN19:
Two values are transmitted synchronously from
the NC program to the PLC.
FN29:
Up to eight values are transmitted
asynchronously from the NC program to the
PLC.
CYCLE13:
Define spindle position for M19
TCHPROBE:
Call the measuring cycles.
GFUNCTION:
G functions are transmitted to the PLC. The G
functions, including the function parameters,
are transferred in an M strobe.
RESET
LEVEL3
1583
mCode
104202
Number of the M function
Number of the M function for which the control-
dependent function is mapped.
Format: Numerical value
Input: 0 to 9999
Default: 0
RESET
LEVEL3
1584
mOffset
104203
Transferred M code is offset
Format: Selection menu
Input:
TRUE:
The first numerical value transferred is used as
an offset and entered in the parameter MP_min
of the associated M function. The remaining
numerical values are written to the double word
entered in MP_data.
FALSE:
No offset is used. The MANUALplus 620
always issues the M function given under
MP_min. Both transferred numerical values are
written to the array of double words entered in
MP_data.
RESET
LEVEL3
1584
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page