458 HEIDENHAIN Technical Manual MANUALplus 620
mode
104302
Evaluation of override values
Format: Selection menu
Input:
DISCRETE:
The key inputs or potentiometer settings are
converted in up to 25 discrete override values
from MP_values.
LINEAR:
The input from the override device is
interpolated linearly between the minimum and
maximum override value.
CURVE:
The input values of the override device are
converted using the curve defined in
MP_values.
You define the curve with up to 64 interpolation
points in MP_values. The input values of the
override device are again interpolated linearly
above the last interpolation point specified. If no
curve is defined in MP_values, the control uses
a standard curve.
Default: DISCRETE
RESET
LEVEL3
1353
values
104303
(optional parameter)
Discrete values or interpolation points for
curve
The mode of operation of the parameter depends
on the setting in MP_mode:
MP_mode = DISCRETE:
Enter override values for a maximum of 64 key
inputs or potentiometer settings.
MP_mode = LINEAR:
MP_values has no function
MP_mode = CURVE:
Define a curve with up to 64 interpolation
points. The override values are taken from the
curve. Linear interpolation is again effective
above the last interpolation point specified.
Format: Array [0...63]
Input: 0 to 200
RESET
LEVEL3
1354
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page