January 2012 4.10 List of Machine Parameters 459
CfgPlc OverrideS
Configuration of the spindle override
[Key name of spindle]
e.g. S, spindle, etc.
minimal
104401
Minimum value for override
Format: Numerical value
Input: 0 to 100 [%]
Default: 0
RESET
LEVEL3
1355
maximal
104402
Maximum value for override
Format: Numerical value
Input: 0 to 200 [%]
Default: 150
RESET
LEVEL3
1355
source
104403
Source for override values
Format: Selection menu
Input: Device name from
CfgOverrideDev
RESET
LEVEL3
1355
CfgOemBool
User parameter with Boolean data (logical values)
[Key name of the user status value]
The key names of these objects are arbitrary and are defined by the OEM.
If the data is to be copied into the PLC run time image, the key names must match the PLC marker
names, e.g. M4017 (for API 1.0) or NP_MG_Doors_Inactive (for API 3.0), etc.
value
104501
(optional parameter)
List of user status values
(Boolean)
Format: List [1 to 100]
Input: TRUE or FALSE
PLC/Pgm
run is
locked
LEVEL3
1658
ignorePlc
104502
(optional parameter)
Do not copy data object into the PLC image
Format: Selection menu
Input:
TRUE:
The parameter value is not copied to the PLC
run-time system
FALSE:
The parameter value is copied to the PLC run-
time system
PLC/Pgm
run is
locked
LEVEL3
1658