January 2012 4.10 List of Machine Parameters 461
CfgOemPosition
User parameter with fixed-point data (position value)
[Key name of the user fixed-point value]
The key names of these objects are arbitrary and are defined by the OEM.
If the data is to be copied into the PLC run time image, the key names must match the PLC double
word names, e.g. D768 (for API 1.0) or NP_DG_TOOLCH_Pos_Spindle (for API 3.0), etc.
value
104701
(optional parameter)
List of user fixed-point values
(position)
Format: List [1 to 100]
Input: –30 000 to +30 000
max. 4 decimal places
PLC/Pgm
run is
locked
LEVEL3
1658
ignorePlc
104702
(optional parameter)
Do not copy data object into the PLC image
Format: Selection menu
Input:
TRUE:
The parameter value is not copied to the PLC
run-time system
FALSE:
The parameter value is copied to the PLC run-
time system
PLC/Pgm
run is
locked
LEVEL3
1658
PythonSettings
Settings for software option #46 (Python OEM process)
Process
Settings for the automatic start of Python scripts (software option #46)
CfgPythonScript
Python scripts to be started automatically;
Specifies Python processes that are automatically started by the PLC run-time system during startup
and not by calling a PLC module.
The scripts defined below must be activated under CfgPlcPath/pythonScripts.
[Key name of the Python script to be started automatically]
path
120401
Path/name of the Python script
When the soft key entered in the key name is
pressed, the given Python script is started.
Format: String
Input: Path/name of the Python script
Max. 260 characters
PLC/Pgm
run is
locked
LEVEL3
597 110-05
1586
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page