EasyManua.ls Logo

HEIDENHAIN MANUALPLUS 620 - Page 531

HEIDENHAIN MANUALPLUS 620
1818 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
January 2012 4.10 List of Machine Parameters 531
incrPerRevol
400204
(optional parameter)
Increments per revolution of handwheel at
encoder input
Format: Numerical value
Input: Number of increments
Default: 1 024
PLC/Pgm
run is
locked
LEVEL3
1342
rasterPerRevol
400205
(optional parameter)
Detent steps per revolution of handwheel at
encoder input
Format: Numerical value
Input: Number of detent positions
0: Handwheel without detent
Default: 0
PLC/Pgm
run is
locked
LEVEL3
1342
encoderSignal
400206
(optional parameter)
Signal amplitude at position encoder input for
handwheel
Format: Selection menu
Input:
1Vpp:
The input signal of the encoder is a 1 V
PP
signal.
11 uA:
The input signal of the encoder is an 11 µA
signal.
This setting is not supported by the CC 61xx
controller unit! If the value is set nevertheless,
the control outputs the
0400: 11 uA not supported error message.
TTL:
The input signal of the encoder is a TTL signal.
Default: 1 Vpp
PLC/Pgm
run is
locked
LEVEL3
1340
encoderFreq
400207
(optional parameter)
Input frequency of position encoder input for
handwheel
Format: Selection menu
Input:
fast:
Input frequency is 350 kHz
slow:
Input frequency is 50 kHz
Default: fast
PLC/Pgm
run is
locked
LEVEL3
1341
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page

Table of Contents

Other manuals for HEIDENHAIN MANUALPLUS 620

Related product manuals