January 2012 4.10 List of Machine Parameters 539
moveAfterRefType
400410
Type of movement after finding the reference
mark
Format: Selection menu
Input:
absolute:
Absolute positioning. This function is mainly
intended for positioning rotary tables. Please
ensure that no collision occurs as a result of this
positioning. The software limit switches are
already active.
relative:
Incremental positioning
HirthRasterPos:
Approach next Hirth grid position in positive
direction.
HirthRasterNeg:
Approach next Hirth grid position in negative
direction.
Default: absolute
RUN
LEVEL3
806
moveAfterRefPos
400411
Position for positioning after traversing the
reference mark
Format: Numerical value
Input: –100 000.0 to + 100 000.0 [mm]
Default: 0.0 [mm]
RUN
LEVEL3
806
moveAfterRefFeed
400412
Feed rate for positioning after traversing the
reference mark
Format: Numerical value
Input: 10.0 to 36 000 000.0 [mm/min]
or [°/min]
Default: 6000.0 [mm/min] or [°/min]
RUN
LEVEL3
806
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page