January 2012 4.10 List of Machine Parameters 541
maxPosDiff
400605
(optional parameter)
Maximum position difference between
position and shaft-speed measuring system
Format: Numerical value
Input: 0.000 to 100 000.000 [mm]
Default: 0
RUN
LEVEL3
597 110-03
952
posDiffCountDir
400604
(optional parameter)
Counting direction of the motor encoder
Format: Selection menu
Input:
positive:
Motor encoder counts in positive direction
negative:
Motor encoder counts in negative direction
Default: positive
RUN
LEVEL3
597 110-03
952
reserve1
400606
(optional parameter)
Parameter reserved, do not assign RUN
LEVEL3
–
reserve2
400607
(optional parameter)
Parameter reserved, do not assign RUN
LEVEL3
–
reserve3
400608
(optional parameter)
Parameter reserved, do not assign RUN
LEVEL3
–
Parameter
MP number
iTNC MP number
Function and input Reaction/