January 2012 4.10 List of Machine Parameters 541
maxPosDiff
400605
(optional parameter)
Maximum position difference between
position and shaft-speed measuring system
Format: Numerical value
Input: 0.000 to 100 000.000 [mm]
Default: 0
RUN
LEVEL3
597 110-03
952
posDiffCountDir
400604
(optional parameter)
Counting direction of the motor encoder
Format: Selection menu
Input:
positive:
Motor encoder counts in positive direction
negative:
Motor encoder counts in negative direction
Default: positive
RUN
LEVEL3
597 110-03
952
reserve1
400606
(optional parameter)
Parameter reserved, do not assign RUN
LEVEL3
reserve2
400607
(optional parameter)
Parameter reserved, do not assign RUN
LEVEL3
reserve3
400608
(optional parameter)
Parameter reserved, do not assign RUN
LEVEL3