542 HEIDENHAIN Technical Manual MANUALplus 620
CfgEncoderMonitor
Hardware monitoring functions for the position encoders
checkAbsolutPos
400701
MP20.0
Monitoring the absolute position for distance-
coded position encoder
Format: Selection menu
Input:
on:
Monitor the absolute position
off:
No monitoring
Default: off
RUN
LEVEL3
666
checkSignalLevel
400702
MP20.1
Monitoring the amplitude of the position-
encoder signal
Format: Selection menu
Input:
on:
Monitor the encoder amplitude
off:
No monitoring
Default: off
RUN
LEVEL3
666
checkFrequency
400703
MP20.2
Monitoring the edge separation of the position
encoder
Format: Selection menu
Input:
on:
Monitor the encoder frequency
off:
No monitoring
Default: off
RUN
LEVEL3
666
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page