92 2 Installation and Specifications
2.3 Software setup
Encoder configuration
The Encoders and Misc screens contain data and choice fields for
configuring the encoders.
Encoders screen
The Encoders screen configuration fields include:
Axis selection
Encoder resolution
Encoder type TTL or analog)
Reference mark selection
Machine zero offset (MZ Cnts)
Reversing encoder count direction
Units of measure
To configure encoder settings in the Encoders screen:
U Press MENU/SETUP to display the setup menu and then highlight
the Encoders menu item.
U Highlight the Axis choice field and then press a soft key to select the
desired axis.
U Highlight the Res data field and then enter the encoder resolution in
the units shown in the Units choice field.
The setup process for all axes is identical.
Encoders menu item is highlighted Press an axis soft key Enter the encoder resolution