EasyManua.ls Logo

HEIDENHAIN TNC 320 - Cycle Parameters

HEIDENHAIN TNC 320
465 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Touch Probe Cycles: Special Functions
16.2 MEASURE (Cycle 3)
16
422
HEIDENHAIN | TNC 320 | User’s manual for cycle programming | 9/2016
Cycle parameters
Parameter number for result?: Enter the number
of the Q parameter to which you want the TNC
to assign the first measured coordinate (X). The
values Y and Z are in the immediately following Q
parameters. Input range: 0 to 1999
Probing axis?: Enter the axis in whose direction
the probe is to move and confirm with the ENT key.
Input range: X, Y or Z
Probing angle?: Angle, measured from the defined
probing axis in which the touch probe is to move.
Confirm with ENT. Input range –180.0000 to
180.0000
Maximum measuring range?: Enter the maximum
distance from the starting point by which the touch
probe is to move. Confirm with ENT. Input range
-99999.9999 to 99999.9999
Feed rate measurement: Enter the measuring feed
rate in mm/min. Input range 0 to 3000.000
Maximum retraction distance?: Traverse path in
the direction opposite the probing direction, after
the stylus was deflected. The TNC returns the touch
probe to a point no farther than the starting point,
so that there can be no collision. Input range 0 to
99999.9999
Reference system? (0=ACT/1=REF): Define
whether the probing direction and measuring result
should reference the current coordinate system
(ACT, can be shifted or rotated) or the machine
coordinate system (REF):
0: Probe in the current system and save the
measuring result to the ACT system
1: Probe in the fixed machine REF system and save
the measuring result to the REF system.
Error mode? (0=OFF/1=ON): Specify whether the
TNC is to issue an error message if the stylus is
deflected at cycle start. If mode 1 is selected, the
TNC saves the value -1 in the 4th result parameter
and continues the cycle:
0: Error message output
1: No error message output
NC blocks
4 TCH PROBE 3.0 MEASURING
5 TCH PROBE 3.1 Q1
6 TCH PROBE 3.2 X ANGLE: +15
7 TCH PROBE 3.3 ABST +10 F100 MB1
REFERENCE SYSTEM: 0
8 TCH PROBE 3.4 ERRORMODE1