July 02 Mounting and Electrical Installation TNC 370 D 3–27
3.7.12 PLC input/output unit PL 410 B/ PL 405 B
Up to two PL 410 B and one PL 405 B can be connected to the LE 370 D.
X47 PL 410 B/PL 405 B input/output unit on the LE
Logic unit Connecting cable Id. Nr. 289 111 .. 1st PL 410 B
X47 D-sub
terminal
(male)
25-pin
Assignment D-sub
connector
(female)
25-pin
D-sub
connector
(male)
25-pin
X1 D-sub
terminal
(female)
25-pin
Assignment
1 0 V 1 Brown, Yellow, Pink, Red,
Violet
1 1 0 V
2 0 V 2 Red/Blue, Brown/Green,
Yellow/Brown, Gray/Brown,
Pink/Brown
2 2 0 V
3 0 V 3 Brown/Blue, Brown/Red,
Brown /Black, Yellow/Gray,
Yellow/Pink
3 3 0 V
4 Do not use 4 Gray/Green 4 4 Serial IN 2
5
Address 6
5 White/Green 5 5
Address 6
6 INTERRUPT 6 Pink/Green 6 6 INTERRUPT
7
RESET
7 Green/Blue 7 7
RESET
8
WRITE EXTERNAL
8 White/Blue 8 8
WRITE EXTERNAL
9 WRITE EXTERNAL 9 White/Red 9 9 WRITE EXTERNAL
10
Address 5
10 Gray/Pink 10 10
Address 5
11
Address 3
11 Blue 11 11
Address 3
12
Address 1
12 Green 12 12
Address 1
13 Do not use 13 13 13 Do not use
14 PCB identifier 4 14 Yellow/Blue, Pink/Blue,
Yellow/Black
14 14 + 12 V
15 PCB identifier 3 15 Yellow/Red, Gray/Red,
Pink/Red
15 15 + 12 V
16 Do not use 16 Gray/Blue 16 16 PCB identifier 2
17 Do not use 17 Green/Black 17 17 PCB identifier 1
18
Address 7
18 White/Yellow 18 18
Address 7
19 Serial IN 1 19 White/Black 19 19 Serial IN 1
20 EMERGENCY STOP 20 Green/Red 20 20 EMERGENCY STOP
21
Serial OUT
21 White/Gray 21 21
Serial OUT
22 Serial OUT 22 White/Pink 22 22 Serial OUT
23
Address 4
23 Black 23 23
Address 4
24
Address 2
24 Gray 24 24
Address 2
25
Address 0
25 White 25 25
Address 0
Housing External shield Housing External shield Housing Housing External shield