July 02 Machine Parameters TNC 370 D 4–71
4.13 Display and Operation
Machine
parameter
Function and input Change via Reaction
MP7210 Programming station
Input:
0 = controlling and programming
1 = programming station "PLC active"
2 = programming station "PLC not active"
CN Reset
MP7212 POWER INTERRUPTED message
Input:
0 = POWER INTERRUPTED message must
be acknowledged with the CE key
1 = POWER INTERRUPTED message does
not appear
CN
PLC
RUN
MP7220 Block number increment for ISO programs
Input: 0 to 250
CN
PLC
RUN
MP7224 Lock file types
Input: %xxxxxxxx
Bit 0 HEIDENHAIN programs
Bit 1 ISO programs
Bit 2 Tool tables
Bit 3 Datum tables
Bit 8 Point tables
0 = do not lock
1 = lock
CN
PLC
RUN
MP7230
Switching the dialog language
Input: 0 or 1
1 = local language
2 = English
CN
PLC
RUN
MP7237 Reset NC operating times with code
number 857 282
Input: %xxx
Bit 0: reset "CONTROL ON "
Bit 1: reset "PROGRAM RUN"
Bit 2: reset "SPINDLE ON"
PLC
RUN
MP7251 Amount of global Q parameters
Input: 0 to 40
PLC
RUN