EasyManua.ls Logo

HEIDENHAIN TNC 426 PB - Module 9122 Status of PLC Axis

HEIDENHAIN TNC 426 PB
1135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 30 HEIDENHAIN Technical Manual TNC 426, TNC 430
Module 9122 Status of PLC axis
Request for PLC positioning status.
Condition:
n Status changes through the PLC positioning command are not detected
until the next PLC scan.
Call:
PS B/W/D/K <Axis>
0 to 8 correspond to axes 1 to 9
CM 9122
PL B/W/D <Status>
Bit 0 A PLC axis?
0: NC axis or not active
1: PLC axis
Bit 1 Reference mark
0: Reference mark not yet traversed
1: Reference mark traversed
Bit 2 Positioning
0: Inactive
1: Active
Bit 3 Direction of motion
0: Positive
1: Negative
Bit 4 Positioning error
0: No positioning errors occurred
1: Positioning error
Bit 5 Close-loop or open-loop axis
0: Close-loop axis was programmed
1: Axis programmed which was switched to open-loop in
Module 9155
Bit 6 Target position reached?
0: Target position not yet reached
1: Target position reached