6 332 HEIDENHAIN Technical Manual TNC 426, TNC 430
Module 9055 Local time
With Module 9055 you can convert the value read with Module 9195 into a
legible ASCII format. Module 9055 corrects the transferred value by the
difference to local time as entered in MP7235.
Call:
PS B/W/D/K <System time>
Number of seconds since 0:00 hours on January 1, 1970.
PS B/W/D/K <String number>
0 to 7
PS B/W/D/K <Format>
0: DD.MM.YYYY hh:mm:ss
1: D.MM.YYYY h:mm:ss
2: D.MM.YYYY h:mm
3: D.MM.YY h:mm
4: YYYY-MM-DD- hh:mm:ss
5: YYYY-MM-DD- hh:mm
6: YYYY-MM-DD h:mm
7: YY-MM-DD- h:mm
8: DD.MM.YYYY
9: D.MM.YYYY
10: D.MM.YY
11: YYYY-MM-DD
12: YY-MM-DD
13: hh:mm:ss
14: h:mm:ss
15: h:mm
CM 9055
Error recognition:
MP7235 Time difference to Universal Time (Greenwich Mean Time)
Input: 23 to +23 [hours]
0: Universal Time (Greenwich Mean Time)
1: Central European Time (CET)
2: Central European daylight-saving time
Marker Value Meaning
M4203 0 String was generated
1 Incorrect transfer value