December 2001 Touch Probe 6 – 369
MP6321 Measuring the center offset while calibrating the
measuring touch probe
Input: 0: Calibration with measurement of the center offset
1: Calibration without measuring the center offset
MP6322.0-2 Assignment of the touch probe axes to the machines axes
X, Y and Z
Input: 0: Touch probe axis X
1: Touch probe axis Y
2: Touch probe axis Z
MP6330 Maximum deflection of the stylus (measuring touch probe)
Input: 0.1 to 4.000 [mm]
MP6350 Feed rate for positioning to the MIN point and approaching
the contour (measuring touch probe)
Input: 1 to 3000 [mm/min]
MP6360 Probing feed rate (measuring touch probe)
Input: 1 to 3000 [mm/min]
MP6361 Rapid traverse in probing cycle (measuring touch probe)
Input: 10 to 20 000 [mm/min]
MP6362 Feed rate reduction, if the stylus of the measuring touch
probe is deflected to the side
Input: 0: Feed rate reduction not active
1: Feed rate reduction active
MP6370 Radial acceleration when digitizing with measuring touch
probe
Input: 0.001 to 3.000 [m/s]
Recommended input value: 0.1
MP6390 Target window for contour line
Input: 0.1000 to 4.0000 [mm]