December 2001 Tool Changer 6 407
Module 9093 Read data from tables selected for program (.T/.D/.TCH)
Prerequisite for table: M status must be set.
You transfer the line number (i.e. tool number for .T, vector number for .D or
pocket number for .TCH) and the number of the element to be read.
The value is given as a natural number, shifted by the number of decimal
places that can be entered.
The module must be called in a submit job or spawn job.
Call:
PS B/W/D/K <File type (see Module 9092)>
PS B/W/D/K <Line number>
PS B/W/D/K <Element number (see Module 9092)>
CM 9093
PS B/W/D <Element value>
PL B/W/D <Error number>
0: No error
1: Call was not in a submit job
2: File type does not exist
3: No file of the entered type was found with M status
4: Line number not in file
5: Incorrect element number
Error recognition:
Marker Value Meaning
M4203 0 No error
1 For error, see above