December 2001 Data Transfer NC → PLC, PLC → NC 7 – 25
TT touch probe for tool measurement
350 20 1 Center of axis 1
2 Center of axis 2
3 Center of axis 3
21 – Effective radius
22 1 Probing position 1 in axis X
2 Probing position 1 in axis Y
3 Probing position 1 in axis Z
23 1 Probing position 2 in axis X
2 Probing position 2 in axis Y
3 Probing position 2 in axis Z
24 1 Probing position 3 in axis X
2 Probing position 3 in axis Y
3 Probing position 3 in axis Z
25 1 Probing position 4 in axis X
2 Probing position 4 in axis Y
3 Probing position 4 in axis Z
Measuring touch probe
350 30 – Effective length
31 – Effective radius 1
32 – Effective radius 2
33 – Diameter of calibration ring
34 1 Center offset (reference axis)
2 Center offset (minor axis)
35 1 Compensation factor in axis 1
2 Compensation factor in axis 2
3 Compensation factor in axis 3
36 1 Power ratio in axis 1
2 Power ratio in axis 2
3 Power ratio in axis 3
Coordinate transformation
420 0 0 0 = Globally effective
Write values into active datum table
500 Line Column Depends on MP7475
501 Line Column
Velocity semifeedforward control
600 1 Axis Factor for velocity semifeedforward
2 0 or NO ENT Use factor from MP1396.x
Group
name
Group
number
ID....
System data
number
NR....
System data
index
IDX....
System data item