December 2001 Update Information No. 6 1 – 1
1 Update Information No. 6
1.1 Releases
The following NC software was released:
n NC software 280 474-18 and 280 475-18 June 2001
n NC software 280 474-19 and 280 475-19 August 2001
n NC software 280 476-15 and 280 477-15 November 2000
n NC software 280 476-16 and 280 477-16 December 2000
n NC software 280 476-17 and 280 477-17 March 2001
n NC software 280 476-18 and 280 477-18 April 2001
n NC software 280 476-19 and 280 477-19 July 2001
n NC software 280 476-20 and 280 477-20 August 2001
n NC software 280 476-21 and 280 476-21 November 2001
1.2 NC software 280 474-xx
NC software Setup Disks Release
280 474-18 286 195-21 06/2001
Export version:
280 475-18 286 195-21 06/2001
NC Software Setup Disks Release
280 474-19 286 195-22 08/2001
Export version:
280 475-19 286 195-22 08/2001
1.3 NC software 280 476-xx
NC software Setup Disks Release
280 476-15 286 197-17 11/2000
Export version:
280 477-15 286 197-17 11/2000
Machine
parameters
n MP7441 has been expanded:
Bit 1: Reserved, enter 0
Bit 2: Error message “Enter depth as negative” when a positive depth was
programmed in the fixed cycles.
= 0: Error message is suppressed
= 1: Error message is not suppressed
n MP7682 has been expanded:
Bit 3: Reserved, enter 0
Bit 4: Reserved, enter 0
Machine
integration
n Before a probing block, the control checks whether M4501 is set. If it is, the
probing block start is delayed by 1 second.