10 4 HEIDENHAIN Technical Manual TNC 426, TNC 430
In the following error messages, in addition to the error code, a number is
output with the following meanings:
n y = 0: DSP axes of axes 1 to 6
n y = 1: Spindle DSP
n y = 2: DSP axes of axes 7 to 9
DSP ERROR C00A Triangular signal pulse-width modulation (hardware
problem or wrong value in MP2180)
280 474-04
DSP ERROR C00B Error upon memory request (data processing error)
DSP ERROR C00C No velocity control interrupt (data processing error)
DSP ERROR C00D Checksum error, code (data processing error)
DSP ERROR C00E Timeout of the speed interrupt (data processing error)
DSP ERROR C00F Error when initializing a software timer (data processing
error)
DSP ERROR C010 Error during LSV2 transmission (data processing error)
DSP ERROR C011 Drive start without previous synchronization (data
processing error)
DSP ERROR C012 No TL and sync-source initializing (data processing error)
Error message Cause of error, corrective action As of
NC SW
Error message Cause of error, corrective action As of
NC SW
DSP ERROR 1000 y Timeout during a command (data processing error) 280 470-01,
280 472-01,
280 474-01
DSP ERROR 1001 y Incorrect acknowledgment of a command (data processing
error)
DSP ERROR 1002 y Command is sent before the previous command is
acknowledged (data processing error)
DSP ERROR 1003 y Synchronization error between DSP and NC (data
processing error)
DSP ERROR 1004 y Incorrect message DSP/NC (data processing error)
DSP ERROR 1005 y Too many commands NC/DSP (data processing error)
DSP ERROR 1100 y Error during the checksum calculation (data processing
error)
DSP ERROR 1101 y Timeout during word transfer command, loading DSP code
(data processing error)
DSP ERROR 1102 y Timeout during the checksum calculation (data processing
error)
DSP ERROR 1103 y Timeout during GO command (data processing error)
DSP ERROR 1104 y File not found (data processing error)