EasyManua.ls Logo

HEIDENHAIN TNC 430 PA - Page 229

HEIDENHAIN TNC 430 PA
1135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
December 2001 3 147
3.25.8 Basic Circuit Diagram TNC 426 M, TNC 430 M with SIMODRIVE 611D in Double Row
T4
T4
LE 426 M
LE 430 M
24 V
24 V
K8
72
73.1
SSK 1
24 V PLC
K1
K5
X73/6
X73/7
AS
K2
K3
K6 K7 K8
SSK 2
K4
K5
SSK 3
K4
K5
K2
K3
K3
K2
K4
K5
K6
K7
PWM
3
2
SH2
FR+
K6 K7
K2 K3
9
48
73.1
72
K7
K6
63
64
9
FR+
NS1
NS2
U
Z
FR
SSK 1
5 V
AS1
AS
U
I
2
M
X34/1 X41/34
0 V
X34/2
X42/33X42/4
3
X44/1 X44/2 X44/3 X44/4
K4
K3K2
Power fail
Uz
+Uz
X31
X15-X20
X60,X62-X64
X69
X51-X59
X61
X1-X6
X35-X38
R
T
K2 K3
F2A
F2A
Reset
Power fail
PE
F2A
UV 111x
FR+
K6
K7
AS2
2
CCU
K9
K663
SH1B
SSK 1
+15 V
15 V
+12 V
12 V
+ 5 V
 5 V
L2L1 L3
PE
UV W
3
X51-
X61
X1,X2
PLC output
Position
Speed
Rotor position
Motor temperature
Standby
Temperature warning
Control ready
for operation
Machine control
voltage on
Permissive button 1
Enabling
operation
Door contact switch 1
Functional test
Door contact switch 2
Functional test
PMW enable
Automatic
operation
Functional test
Emergency Stop
Safety
contactor
combination
Measuring voltage
U
Z
5 V
Unit bus
Supply Unit
Standby
Monitoring heat exchanger
Monitoring 5V
Pulse resistor
module
Pulse resistor
Supply optocoupler
Power component
Simodrive 611 D
HEIDENHAIN
Interface PCB
Holding brake
Power supply
Monitoring
Supply unit
-standby
Emergency
Stop
Limit switch
Key-operated
switch
I
actl
Permissive button 2
Emergency Stop
controlled
Acknowledgement
of control ready
Rectifier
Power supply
Drive enable
t=approx. 1s
t=approx. 1s
Line filter
Master
switch
Commutating
reactor
HEIDENHAIN
protective PCB

Table of Contents

Other manuals for HEIDENHAIN TNC 430 PA

Related product manuals