December 2001 Hardware 2 29
2.4 Hardware
2.4.1 Designation of the Logic Unit
ID number of the logic unit:
The basic ID number indicates hardware differences.
This first digit of the variant number indicates hardware changes.
The second digit of the variant number specifies the option:
Option
number
Meaning
3 Export version with digitizing with triggering touch probe
option
4 Standard version with digitizing with triggering touch probe
option
7 Standard version with digitizing with measuring and triggering
touch probe option
8 Export version without option
9 Standard version without option
Variant Changes to LE 426 C/P, LE 430 C/P
xxx xxx-2x Initial version
xxx xxx-3x Stronger rectifier in power supply
xxx xxx-4x 4 MB RAM; 3-row VGA connection;
3-phase current controller
xxx xxx-5x Power supply unit with higher performance
Variant Changes to
LE 426 M, LE 430 M
324 990-xx to 324 997-xx
Changes to
LE 426 M, LE 430 M
344 958-xx to 344 965-xx
xxx xxx-1x flash EPROMs,
all encoder inputs with EnDat
interface
xxx xxx-2x Initial version
xxx xxx-3x New hard disk suspension,
certain position encoder inputs
with EnDat interface
312 001-27