6 – 486 HEIDENHAIN Technical Manual TNC 426, TNC 430
7
77
7 Transfer the resulting jerk value from MP1090.0 to the axis specific
parameters MP1097.x and MP1098.x.
7
77
7 Increase the k
v
factor until the oscillation limit is reached.
7
77
7 Calculate MP1510:
MP1510.x = <determined value> · 0.6
MP1090 too small
Oscillation limit has been reached