EasyManua.ls Logo

HEIDENHAIN TNC 430 PA - Load Not (Ln)

HEIDENHAIN TNC 430 PA
1135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 88 HEIDENHAIN Technical Manual TNC 426, TNC 430
7.7.4 LOAD NOT (LN)
Logic processing
with the LOAD NOT
command
Syntax: LN (LOAD NOT)
Operands: M, I, O, T, C
Action:
Load the complement of the addressed operand into the logic accumulator.
Always use the L command at the beginning of a logic chain in order to be able
to gate the operand in the following program sequence.
Example:
Gate the inverted logical state of inputs I4 and I5 with AND, and assign the
result to output O2.
Initial state:
Input I4 = 0
Input I5 = 1
Output O2 = ?
Function STL Accumulator contents [bit] Operand contents [bit]
31..15 .................... 7 ................. 0
Load the inverted
operand content into
the logic
accumulator.
LN I4 x ..... x xxxxxxx1xxxxxxx 0
Gate the content of
the logic
accumulator and
input I5 with AND.
A I5 x ..... x xxxxxxx1xxxxxxx 1
Assign the gating
result to output O2.
= O2 x ..... x xxxxxxx1xxxxxxx 1

Table of Contents

Other manuals for HEIDENHAIN TNC 430 PA

Related product manuals