22
Rotary switch for selection the fan speed control:
By setting the speed control knob (E) the desired speed level can be
selected:
OFF = Speed Off
1 = Low speed
2 = Medium speed
3 = High speed
Rotary switch for setting mist volume:
CLOSE = Setting is closed
OPEN = Setting is opened
Setting mist volume
strong slight
Adjustments
Caution: The fan should always be switched off (all function) and always disconnected
from the mains supply when making this adjustment:
Oscillation:
The oscillation is factory-preset to OFF position.
By offsetting the position of the oscillation-bracket and the fixing screw, which are located below the
motor-housing, the oscillation can be set on ON-position:
Turn the screw out completely.
Put the oscillation-bracket on the bottom hole opening.
Turn the oscillation-bracket with the fixing screw again firmly.
Oscillation - Position OFF Oscillation - Position ON
If the oscillation function is not required proceed in reverse order.
Changing of the motor position:
The angle of the fan head can be changed by loosening the adjustment screw on the engine-joint. Move
the fan head to the desired angle up or down and fixing the screw firmly again. Check for a firm and
proper fixing.