Table 1.
SAUNA HEATER
SAUNA
MINIMUM DISTANCES
CABLES
Model
Output
Volume
min.max.
Height
H min.
From the sauna heater
Sensor
Control
panel /
contactor
box
Sauna
heater
H07RN-F /
60245 IEC
66
Front
fuse
to the side wall
A
to the ceiling
F
to the front (safety rail)
and top bench
A
to the back C
A psolutely required
kW
m
3
m
3
mm
mm
mm
mm
mm
mm
2
mm
2
mm
2
A
1105-901
9,0
8
13
1900
80
1200
80
110
4 x 0.25
5 x 2.5
5 x 2.5
16
1105-1051
10,5
9
15
1900
80
1200
80
110
4 x 0.25
5 x 2.5
5 x 2.5
16
1105-1201
12,0
10
18
2100
120
1400
120
120
4 x 0.25
5 x 4
5 x 4
20
1105-1501
15,0
14
24
2100
120
1400
120
120
4 x 0.25
5 x 6
5 x 6
25
Control panel: 1410-33-… and 2005-6
1. Control panel
2. Sensor
3. Heat-proof cable
4. Sauna heater supply cable
5. Connection box
6. Sauna heater connection cable
7. Lower bench or safety rail
X) = The given minimum distance is absolutely
required, no deviation allowed.
H min
min
A
F min
7
3
2
1
40 mm
m in
50
C
(X
max
500
min
A
5
6
4
(x
5
Image 1
Image 1
2
3
1
4
8 A A
4
50
5
6
min
7
H min
max 500
F min
40
(x

Other manuals for Helo 1601-13