Electrical connections
The sauna heater must be connected to the mains by a qualified electrician and in compliance with current
regulations. The steam generator is connected with a semi-permanent connection. Use H07RN-F (60245 IEC 66) or
a corresponding type cables
Output
kW
Generator con-
nection cable
H07RN-F / 60245
IEC 66
mm
2
400V-415V 3N~
Fuse
A
Generator con-
nection cable
H07RN-F / 60245
IEC 66
mm
2
230V 3~
Fuse
A
Generator connec-
tion cable
H07RN-F /
60245 IEC 66
mm
2
230V-240V 1N~/2~
Fuse
A
3.4 5 x 1.5 3 x 10 4 x 1.5 3 x 10 3 x 2.5 16
4.7 5 x 1.5 3 x 10 4 x 2.5 3 x 16 3 x 6.0 25
6.0 5 x 1.5 3 x 10 4 x 2.5 3 x 16 3 x 6.0 25
7.7 5 x 2.5 3 x 16 4 x 6 3 x 25 3 x 10 35
9.5 5 x 2.5 3 x 16 4 x 6 3 x 25
------ ------
12.0 5 x 6 3 x 25 4 x 10 3 x 35
------ ------
14.0 5 x 6 3 x 25 4 x 10 3 x 50
------ ------
Steam generator's heating elements
Teho
Power
Leistung
Vastus / Element / Heizstäbe 230V
1 2 3
3.0
3.4
4.7
6
7.7
1,000W / SEPD 131
1,150W / SEPD 97
1,567W / SEPD 98
2,000W / SEPD 99
2,567W / SEPD 100
1,000W / SEPD 131
1,150W / SEPD 97
1,567W / SEPD 98
2,000W / SEPD 99
2,567W / SEPD 100
1,000W / SEPD 131
1,150W / SEPD 97
1,567W / SEPD 98
2,000W / SEPD 99
2,567W / SEPD 100
9.5
12
14
5,250W / SEPD 116
4,250W / SEPD 119
5,250W / SEPD 116
3,500W / SEPD 115
3,500W / SEPD 115
3,500W / SEPD 115
5,250W / SEPD 116
4,250W / SEPD 119
5,250W / SEPD 116
Connection diagrams
Electrical connections
3,4 - 14 kW 400V - 415V 3N~
G A B C D E F S
L1 L2 L3 N
3,4 - 14 kW 230 V 3~
G A B C D E F S
L1 L2 L3
3,4 - 7,7 kW 200V - 240V 1N~ / 2~
G A B C D E F S
200V - 240V~
User and installation manual HNS-T1