EasyManua.ls Logo

Helo HNS T1 - Electrical Connections and Output Selection

Helo HNS T1
182 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical connections
The sauna heater must be connected to the mains by a qualified electrician and in compliance with current
regulations. The steam generator is connected with a semi-permanent connection. Use H07RN-F (60245 IEC 66) or
a corresponding type cables
Output
kW
Generator con-
nection cable
H07RN-F / 60245
IEC 66
mm
2
400V-415V 3N~
Fuse
A
Generator con-
nection cable
H07RN-F / 60245
IEC 66
mm
2
230V 3~
Fuse
A
Generator connec-
tion cable
H07RN-F /
60245 IEC 66
mm
2
230V-240V 1N~/2~
Fuse
A
3.4 5 x 1.5 3 x 10 4 x 1.5 3 x 10 3 x 2.5 16
4.7 5 x 1.5 3 x 10 4 x 2.5 3 x 16 3 x 6.0 25
6.0 5 x 1.5 3 x 10 4 x 2.5 3 x 16 3 x 6.0 25
7.7 5 x 2.5 3 x 16 4 x 6 3 x 25 3 x 10 35
9.5 5 x 2.5 3 x 16 4 x 6 3 x 25
------ ------
12.0 5 x 6 3 x 25 4 x 10 3 x 35
------ ------
14.0 5 x 6 3 x 25 4 x 10 3 x 50
------ ------
Steam generator's heating elements
Teho
Power
Leistung
Vastus / Element / Heizstäbe 230V
1 2 3
3.0
3.4
4.7
6
7.7
1,000W / SEPD 131
1,150W / SEPD 97
1,567W / SEPD 98
2,000W / SEPD 99
2,567W / SEPD 100
1,000W / SEPD 131
1,150W / SEPD 97
1,567W / SEPD 98
2,000W / SEPD 99
2,567W / SEPD 100
1,000W / SEPD 131
1,150W / SEPD 97
1,567W / SEPD 98
2,000W / SEPD 99
2,567W / SEPD 100
9.5
12
14
5,250W / SEPD 116
4,250W / SEPD 119
5,250W / SEPD 116
3,500W / SEPD 115
3,500W / SEPD 115
3,500W / SEPD 115
5,250W / SEPD 116
4,250W / SEPD 119
5,250W / SEPD 116
Connection diagrams
Electrical connections
3,4 - 14 kW 400V - 415V 3N~
G A B C D E F S
L1 L2 L3 N
3,4 - 14 kW 230 V 3~
G A B C D E F S
L1 L2 L3
3,4 - 7,7 kW 200V - 240V 1N~ / 2~
G A B C D E F S
200V - 240V~
User and installation manual HNS-T1
9

Table of Contents