13
DISCHARGING AND FLUSHING:
A separate electrically-operated valve with a separate automatic drain and rinsing operation is
available for the steamer (Accessory). The electrically-operated drain valve opens once 15 minutes
has passed since the steamer shuts down.
This function is available in both control panel and button operation versions.
In the button version the LED will flash in one-second intervals during the 15-minute discharge and
flushing wait period after the steam generator has shut off.
After the tank has been discharged, the steam generator will wait for the next start command.
DISCHARGE VALVE :
Installation of the HSX steam generator:
- Use the duct tape included (as a minimum) to seal the electrically-operated valve threads.
- Connect the included electrically-operated valve power cord to the power mains.
- Run a discharge pipe from the discharge valve into a drain. NOTE! Because water will run at its
own pressure, the steam generator
should be installed some distance away from the drain.
ALARMS:
Control panel
E1 When switching on or with the steam generator already running, the water faucet is shut or
water is for some other reason being prevented from flowing into the steam generator. Turn on the
water faucet. If the fault is in the steam generator, it may require servicing.
E2 The fault alarm will be given when the serial traffic between the control panel and circuit board
malfunctions.
Requires service to find the cause of the fault.
When the fault alarm is given, the steam generator will shut down. Repair the cause of the fault or
call an authorised service technician. Malfunctions can be reset by pressing the ON/OFF button.
In button-equipped versions the button LED will flash rapidly when the fault is detected; the steam
generator is running when the water faucet is shut or for some other reason water is being prevented
from flowing into the steam generator. This alarm is also given when the water feed is cut while the
steam generator is running. The malfunction can be reset by pressing the button. Repair or replace
the cause of the fault.
The circuit board output for an external alarm is 12 V DC max 50 mA. The output is activated when
alarm E1 or E2 is displayed or the LED flashed rapidly. The alarm is reset by pressing the ON/OFF
button.