2.1.42 ESC [F0]+[09]+[07]+[n1]..[n7] 2D Bar code configuration
[Name] 2D Bar code configuration
[Function] This command selects a 2D bar code and sets the conditions for printing it.
[Code] [1B]
16
+ [F0]
16
+ [09] + [07] + [n1]..[n7]
[27]
10
+ [240]
10
+ [09] + [07] + [n1]..[n7]
[Description]
1. Command “ESC [F0]+[09]+[07]+[n1]..[n7]” selects a two-dimensional (2D) bar code type and sets
the conditions to be used for printing it. This command does not initiate the printing of 2D bar
code itself. See “2D Bar code printing” for the details on printing the bar code itself. The
eXtendo
®
printer will determine and print the bar code based on the settings from this command
and the data sent to it for encoding from the “2D Bar code printing” command. The eXtendo
®
is
also capable of printing any bar code of appropriate resolution sent to it as a graphics file.
2. Parameter [n1] specifies the type of 2D bar code to be printed.
n1 Style
0 PDF417
1 Datamatrix
2 QR Code
3. Parameter [n2] specifies the 2D bar code style, depending upon the bar code selected. It sets
the Style for PDF417.
n2
PDF417
Style
0 Normal style
1 Truncated style; no stop pattern or right row indicator
[n2] determines how the encoded input data will be interpreted, based on the following table.
n2
Datamatrix Data Format
0 Auto
1 ASCII
2 C40
3 Text
4 Base 256
For QR Code printing, parameter [n2] specifies the symbol version type between 1 and 6. (For
example, n2 = 4 means print a version 4 QR code). For QR codes, the symbol version describes
the size (i.e. the number of characters) of the symbol. If this parameter is set to 0, the lowest
possible version is chosen according to the number of data bytes. If the number of sent data
bytes exceeds the number of maximum bytes of the currently selected version the byte stream is
truncated to the maximum length.