Em ulation Command Set Reference
Part No. D 684 112 Mod.Nr. 4 150813 LEV Page 71 of 95
2.1.52 ESC [F1]+[01]+[0C]+[04]+[m1]..[m11] Burn Time Correction
[Name] Burn Time Correction
[Function] This command is used to adjustments in burn time at different temperature
settings.
[Code] [1B]
16
+ [F1]
16
+ [01]
16
+ [0C]
16
+ [04]
16
+ [m1] ... [m11]
[27]
10
+ [241]
10
+ [01]
10
+ [12]
10
+ [04]
10
+ [m1] ... [m11]
[Description]
1. The “ESC [F1]+[01]+[0C]+[04]+[m1]..[m11]” command specifies corrections to burn time based on
ambient temperature.
2. The variables [m1] to [m11] are 8-bit, signed integers that specify the burn time adjustment in µs.
3. The adjustment range of [m1] to [m11] is from -125 to +125 µs.
4. The variables [m1] to [m11] relate to the temperature as follows.
Variable
Temperature
m1 -30ºC
m2 -20ºC
m3 -10ºC
m4 0ºC
m5 +10ºC
m6 +20ºC
m7 +30ºC
m8 +40ºC
m9 +50ºC
m10 +60ºC
m11 +70ºC
5. The intended purpose of the Burn Time Correction is to adjust the eXtendo
®
temperature
response at various ambient temperatures to match different, Hengstler-approved thermal paper
types.
6. Sample wide fonts (standard and KS5601-Korean) are provided in the driver package.