2.1.57 ESC [F1]+[01]+[02]+[07]+[n] Customer Flag Setting
[Name] Customer flag setting command
[Function] This command sets or resets the customer flags
[Code] [1B]
16
+ [F1]
16
+ [01]
16
+ [02]
16
+ [07]
16
+ [n]
[27]
10
+ [241]
10
+ [01]
10
+ [02]
10
+ [07]
10
+ [n]
[Description]
1. The “ESC [F1]+[01]+[02]+[07]+[n]” command is used to specify the state of the two customer
flags.
2. The customer flag settings are stored in flash memory, whereas each defined flag can either be 1
or 0.
3. The customer flags are intended to be used to distinguish multiple printers that are connected to
a single host. The printer transmits the flags in the Status Packets (see command “GS a + [n]”,
Request Printer Status)
4. Customer flags are to be specified in an 8-bit unsigned byte, whereas the least significant bit is
status flag #1 and the next bit is status flag #2.
5. Following customer flags are defined:
Bit Description Contents
0
Customer status flag #1 for the
eXtendo
®
status message (see “GS
a+[n]”)
0: Disabled 1: Enabled
1
Customer status flag #2 for the
eXtendo
®
status message (see “GS
a+[n]”)
0: Disabled 1: Enabled
2-15 Reserved 0 (this value should always be set to "0")