$UWLFOH 1R 5HY
Supplement to the
Operation Manual
signo 723.1
Variable Preset Counter
signo 727.1
Position Indicator
RS485 / RS232 Protocol Hengstler TP3
This description is a supplement to the manual
2 723 093
(for signo 723.1) and
2 727 033
(for
signo 727.1).
It contains the feature description of the interface
options for the counters. It also contains hints
required for the installation and connection of a
counter to an RS 485 bus or to RS 232.
Ordering information
Interface-
option
Power-supply Ordering code
signo 723*
Ordering code
signo 727*
Ordering code
RTC**
Ordering code
signo 723Print***
RS 485 12..24
VDC 0 723 160M3 0 727 160M3 0 723 169
RS 485 115..230 VAC 0 723 161M3 0 727 161M3 0 723 169
RS 232 12..24 VDC 0 723 150M3 0 727 150M3 0 723 150M1
RS 232 115..230 VAC 0 723 151M3 0 727 151M3 0 723 151M1
* This ordering code characterizes the interface protocol option TP3.
** An RTC is required when connecting one or more counters to an RS 485 bus.
*** 723Print with only Write-function and baudrate 4800 Baud. (See also 2 723 085)
Interface parameters
Two interface parameters have been added to
service level 3:
Parameter Display Alternatives Meaning
Baud Rate
'F14' 1.2
2.4
4.8 *
1200 baud
2400 baud
4800 baud
Bus Address
'F19' 0
1
...
31
Interface deactivated
physical address 1
...
physical address 31
* Factory set, compare F30
Please set
F14
and
F19
according to the values of your network configuration. The settings for data, parity and