Sach-Nr. 2 727 022 Version 1250899MW Seite3/7
2.2.2 Description of in- and outputs
Function Terminal Remarks:
Power supply of position
indicator
AC: Terminal 1-4
DC: Terminal 1-2
at 230 VAC: bridge terminals 2-3;
at 115 VAC: bridge terminals 1-2 and 3-4;
at 12..24VDC:Terminals 3 and 4 are not connected
Relay output for limit
value 1 or limit value 2
Terminal 6-8
or 10-12
change over contact, Remark: these terminals are not
connected at position indicators without limit values
Transistor output for limit
value 1 or limit value 2
Terminal 14 or 15 PNP transistor output 10 mA, Remark: these terminals are
not connected at position indicators without limit values
Sensor power supply Terminal 32 and 31 Supply of sensor with 12...24 VDC / 60 mA (max)
DATA + Terminal 30 differential signal data + (data input from SSI - encoder)
DATA - Terminal 29 differential signal data - (data input from SSI - encoder)
CLOCK + Terminal 28 differential signal clock + (clock output for SSI - encoder)
CLOCK - Terminal 27 differential signal clock - (clock output for SSI - encoder)
Keylock Terminal 26 locking of operation levels can be programmed (see chapter
4.3)
Application input Terminal 25 set value, refernce point, display hold or chain reset, can be
programmed ( see chapter 4.3)
2.3 Description of function of position indicator
The position indicator is working in range mode, i.e. the output signals (Out 1 and Out 2) are set when reaching
the respective limit value. The bistable signal is active until the count value falls below the limit value or the
counter is reset to zero.
Reset to zero or to the set value is done manually from the keyboard or electrically from the reset input.
Example 1: (set value = 0)
limit value 2
limit value 1
Out1
t
Example 2: (set value between limit value 1 and limit
value 2)
limit value 2
limit value 1
Out1
t
set value
3. Operation of the position indicator
3.1 Display and keyboard
DATA
CHAIN
SET
P2
P1
SSI
Area A: Display, in counting mode showing the
actual or absolute position (chain value or absolute
value), and in programming mode the changeable
parameters.
Area B: LED indicators
LED Explanation
P1 OUTPUT
1
of limit value 1 is active
P2 OUTPUT
1
of limit value 2 is active
SET display shows set value
DATA display shows absolute value
CHAIN display shows chain value
Area C: Keyboard: The use of the different keys is
explained in chapter 3.2 .
1
only position indicator with limit value