Seite6/7 Sach-Nr. 2 727 022 Version 1250899MW
Parameter Display Alternatives / Signification
NPN/PNP selection 'F24' '0':
'1':*
KEYLOCK and APPL.are low active, npn switching
KEYLOCK and APPL.are high active, pnp switching
Set funktion key lock
(calibration)
'F26'
'0':*
'1':
if key lock input is active, setting and canceling of calibration
value is not locked
is locked
Level 1 key lock 'F27' '0':*
'1':
if key lock input is active, access to level 1 is not locked
access is locked
Level 2 key lock 'F28' '0':*
'1':
if key lock input is active, access to level 2+3 is not locked
access is locked
F1 and F2 key lock 'F29' '0':*
'1':
'2':
'3':
if key lock input is active, keys F1 and F2 are not locked
F1 locked
F2 locked
F1 and F2 are locked
Basic setting 'F30' '0':*
'1':
no function
all parameters are set to the * marked values
function of application input
'F31' '0':
'1':*
'2':
setting of reference point
display-hold
chain reset
chain mode 'F35' '0':
'1':*
chain function locked
chain function unlocked
1 hint for funktion of limit value 1: if limit value is absolute, OUT 1 will be active as soon as counter position equals to
limit value 1. If limit value is in relative function, OUT 1 will be active as soon as the counter position equals to limit
value 2 plus limit value 1. Example: limit value 1 = -20, limit value 2 = 100
absolute OUT1 at -20 OUT2 at 100
relative OUT1 at 80 (=100-20) OUT2 at 100
5. Locking keyboard functions
In level 3, the following keyboard functions can be locked: Calibration function, entry to level 1, entry to level 2,
buttons F1 and F2. The setting of those keylocks is explained in chapter 4.3.
6. failures and error messages
failure diagnosis
no display • check if supply voltage is correctly connected/ switched on?
limit and set values
are not programmable
• check if level 1 or F1/F2 buttons are locked?
• check if level 2 is locked?
Set function not
possible (calibration
function)
• keylock set function active?
position indicator
does not operate
• check if counting input is correctly connected?
• check if display-hold is triggered?
• check if mass connection position indicator-encoder is correct?
• check if encoder is in good condition?
SSI error • data format incorrectly set
• wiring incorrect or connection defective
failure diagnosis
SSI error • no data compatibility at multiple reading
• parity check active and no parity output from encoder
-...... • range exceeded; tune back to the range or set display to defined value.
_...... • fallen below range; tune back to the range or set display to defined value
If any failure occurs, which is not mentioned above, our sales support for electronic counters will assist you.
(Tel. 07424/89-0).