EasyManua.ls Logo

HERBORNER pumpentechnik herborner.X Series - User Manual

HERBORNER pumpentechnik herborner.X Series
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Coated swimming pool water circulation pump
100% COATING = 0% CORROSION!
X
herborner.
Operating manual Model X
X-PM
X-C
J.H. Hoffmann GmbH & Co. KG | Littau 3-5 | DE-35745 Herborn | Telephone: +49 (0) 27 72 / 933-0
Fax: +49 (0) 27 72 / 933-100 | E-mail: info@herborner-pumpen.de | www.herborner-pumpen.de
A-hX 03 GB
Translation of the original
operating manual
®

Table of Contents

Questions and Answers

  • A
    Andrew FreemanAug 7, 2025
    What to do if my HERBORNER pumpentechnik Swimming Pool Pump vibrates or makes noise?
    • Q
      qmasseyAug 7, 2025
      If your HERBORNER pumpentechnik Swimming Pool Pump is vibrating or making noise, consider the following: * Check the direction of rotation and exchange two phases to the motor if necessary. * Inspect the impeller and replace it if necessary. * Verify the operating conditions to ensure the pump operates in the specified range.
  • K
    Kimberly KellyAug 17, 2025
    Why is my HERBORNER pumpentechnik herborner.X's electric motor overly warm?
    • E
      Eric RobinsonAug 17, 2025
      An overly warm electric motor in your HERBORNER pumpentechnik Swimming Pool Pump can stem from: * Incorrect direction of rotation. Check and correct the motor's rotation, exchanging two phases if needed. * Operating outside the specified range. Verify and adjust the operating conditions. * Excessive density of the pumped medium. Dilute the medium or modify the process. * Obstructions in the supply pipe or impeller. Clean the supply and remove deposits. * Insufficient motor power. Replace with a more powerful model if necessary. * Incorrect motor connection. Ensure the motor is connected to the applicable operating voltage. * High coolant temperature (above 40 °C). Check ventilation paths. * Frequent pump switching. Observe the operating mode.
  • H
    hayesbrianAug 23, 2025
    What to do if my HERBORNER pumpentechnik herborner.X doesn't pump and is in danger of running dry?
    • M
      Mark YoungAug 23, 2025
      If your HERBORNER pumpentechnik Swimming Pool Pump isn't pumping and is in danger of running dry: * De-aerate and fill the pump and pressure pipe. * Clean the supply and remove any sediment deposits from the pump/pipeline. * Open gate valves. * Check the system for any impurities and/or the layout of the pump.
  • S
    Scott RussellAug 27, 2025
    What causes a HERBORNER pumpentechnik Swimming Pool Pump bearing to become hot?
    • R
      ralphcuevasAug 27, 2025
      A hot bearing in your HERBORNER pumpentechnik Swimming Pool Pump could be due to: * Lack of lubrication. Top up grease, replace bearing if necessary. * Too much grease. Remove surplus grease until the balls are just covered. * Pump installed under tension. Connecting pipes must be laid in an unstressed manner. * Defective anti-friction bearing. Exchange anti-friction bearing.
  • J
    Joshua PonceNov 1, 2025
    Why is the delivery of my HERBORNER pumpentechnik Swimming Pool Pump too low?
    • J
      Justin AlexanderNov 1, 2025
      There are several reasons why the delivery of your HERBORNER pumpentechnik Swimming Pool Pump might be too low: * The density of the pumped medium might be too high. If this is the case, dilute the pumped medium or alter the process. * There might be an incorrect direction of rotation of the pump. Check the direction of rotation and exchange two phases to the motor if necessary. * The impeller might be loose or worn. Inspect the impeller and replace it if necessary. * The pump might be pumping against too high a pressure. Measure the pressure, change the configuration, and check the layout of the pump. * Gate valves might be closed too far. Turn the gate valves back. * The pipeline and/or pump might be obstructed. Check the pipeline and/or pump and clean if necessary. * The ...
  • K
    Katie LewisNov 11, 2025
    Why does my HERBORNER pumpentechnik herborner.X Swimming Pool Pump run but immediately switch off?
    • T
      Thomas JacksonNov 11, 2025
      Your HERBORNER pumpentechnik Swimming Pool Pump might run briefly and then switch off due to several reasons: * The motor circuit breaker might have been triggered due to insufficient cooling. Ensure adequate motor cooling. * The motor circuit breaker might have been triggered due to an incorrect direction of rotation. Check the direction of rotation. * The power input may be too high. Check the free movement of the pump. * The density of the pumped medium could be too high. Dilute the pumped medium or alter the process. * The pump may not be operating in the specified operating range. Check the operating conditions. * An obstructed pump may have triggered the motor protection relay. Check the free movement of the pump. * The pump may be switching too often. Observe the oper...

Summary

EC Declaration of Conformity

General Information

Intended Use

Specifies the pump's purpose for swimming pool water circulation and approved applications.

Exploded View

Illustrates the pump's components with part numbers for X/X-PM and X-C models.

Wear Parts

Lists components subject to wear and recommended quantities for a two-year operation.

Technical Specifications

Details model designation, motor ratings, materials, and flange positions.

Dimensions, Weights, Performance Data

Refers to sections with detailed measurements, weights, and performance data.

General Data

Covers media and ambient temperature ranges, density, viscosity, and power correction.

Safety

Notes; Explanations

Explains safety symbols, signal words, and machine identification requirements.

Integrated Safety Systems (Optional)

Describes optional systems like Seal-Guard-System and ETS X4 for pump protection.

Obligations of the Operator

Outlines the operator's responsibilities regarding personnel, equipment, and environmental compliance.

General Hazard Warnings

Dangers

Warns about potential hazards during maintenance and repair work.

Shut Off Procedures

Details the mandatory five safety rules for disconnecting electrical power before work.

Transport

Transport and Packaging

Covers checks, packaging methods, and handling during shipping and receiving.

Transport to the Site of Installation (by the Customer)

Provides guidance on safe transport methods using forklifts or cranes.

Transport with a Crane

Details safe practices for lifting and transporting the pump using a crane.

Installation; Fitting

Installation

Describes preparation of the foundation and pump installation requirements.

Dimensions

Provides tables with physical dimensions for various pump models.

Technical Specifications

Lists technical specifications like motor data, sound pressure levels for different models.

Electrical Connection

Outlines requirements and precautions for establishing the electrical connection by an electrician.

Motor Protection

Explains how to protect the motor using circuit breakers and temperature monitors.

Direction of Rotation Check

Emphasizes checking the pump's rotation direction for correct operation and damage prevention.

Variable Frequency Operation

Discusses variable frequency drives and their compatibility with specific pump models.

Commissioning

Commissioning

Guides through the functional checks and procedures before starting the pump.

Starting Up

Details the step-by-step process for safely starting the pump.

Maintenance; Cleaning

Maintenance

Highlights general maintenance tasks, safety precautions, and regular checks.

Bearing Lubrication

Explains bearing lubrication requirements, intervals, and grease types.

Oil Filling and Oil Change on Versions with Seal-Guard-System

Details procedures for checking and changing oil in the Seal-Guard-System.

Disposal

Instructs on the proper disposal of dismantled components and waste materials.

Disturbance; Cause; Trouble Shooting

Pump doesnt pump. Danger of running dry.

Addresses issues related to insufficient pumping and potential dry running.

Pump runs but immediately switches off.

Troubleshoots common causes for the pump shutting off shortly after starting.

Disassembly; Assembly

Disassembly

Provides step-by-step instructions for taking apart the pump and its components.

Assembly

Guides through the process of reassembling the pump after maintenance or repair.

HERBORNER pumpentechnik herborner.X Series Specifications

General IconGeneral
BrandHERBORNER pumpentechnik
Modelherborner.X Series
CategorySwimming Pool Pump
LanguageEnglish