Technical data
034-11592_1.0_19.11.2018
48
Display
Table 17: Display technical data
Internal battery 2 × 3 V CR2016
Operating temperature -5 °C–40 °C
Storage temperature -10 °C–50 °C
Charging temperature 0 °C–40 °C
Protection rating
(with USB cover closed)
IP54
Weight about 0.1 kg
Emissions
Table 18: Emissions from the bicycle*
A-weighted emission sound pressure level < 70 dB(A)
Total vibration level for the hands and
arms
< 2.5 m/s²
Highest effective value of weighted
acceleration for the entire body
< 0.5 m/s²
*The safety requirements as per Electromagnetic Compatibility
Directive 2014/30/EU have been met. The bicycle and the
charger can be used in residential areas without restriction.
USB port
Table 19: USB port technical data
Charge voltage 5 V
Charging current max. 500 mA
EN_034-11592_1.0_0.01_19.08.2018_HERCULES BOSCH Purion MY19_Inhalt.book Seite 48 Montag, 19. November 2018 11:00 11